LMI Model "GB" Metering
Pumps
-
From the leader in high capacity
chemical feed pumps.
The GB series pumps feature
a mechanically actuated design which eliminates contour plates. Utilizes
standard 56C frame with no special motor required. Rugged construction,
aluminum housing, ductile iron gears and anti-friction ball bearing design.
Accuracy +/-2% between 10% and 100% of rated flow. Lockable micrometer
stroke adjustment can be adjusted while pump is running or stopped. Oil
bath lubrication for all drive components. Standard pump includes 3/4 HP,
TEFC, 56C frame motor and 1/2" female NPT fittings. 10:1 turndown ration
on the manual pump.
These pumps can be purchased
with a variable speed control with 4-20 mA follower to allow you to operate
your pump with a 4-20 mA signal with a 100:1 turndown ration. The 4-20
mA controller also provides the ability to control the pump with an external
sensor. The variable speed drive must be ordered at the time of pump purchase
and will be factory installed. |
| PVC/Teflon/viton wet
end suitable for many acids (not hydrofluosilicic), alkalis, chlorine,
caustics, or potassium permanganate. |
316 SS wet end for use
with polymers and flocculants. |
|
MODEL#
|
GPD
|
PSI
|
|
G518-548P
|
696
|
150
|
|
G528-548P
|
1392
|
150
|
|
G538-548P
|
2784
|
150
|
|
G638-568P
|
3720
|
100
|
|
|
MODEL#
|
GPD
|
PSI
|
|
G518-547P
|
696
|
150
|
|
G528-547P
|
1392
|
150
|
|
G538-547P
|
2784
|
150
|
|
G638-647P
|
3720
|
100
|
|
| VARIABLE
SPEED CONTROL W/ 4-20 mA FOLLOWER (adder) |
|
35639
|
PVC 1/2" PRESSURE
RELIEF VALVE* |
|
35849
|
SS 1/2" PRESSURE
RELIEF VALVE* |
|
| *NOTE:
Pressure relief valves are recommended for all motor driven pumps. These
pressure relief valves operate when the pressure in the chemical system
exceeds the preset pressure of the valve. The diaphragm is held against
the valve seat by an internal spring. When the preset pressure is exceeded,
the diaphragm is forced up and the chemical flows out the relief port,
back to the chemical tank or to the suction side of the pump. The valves
are preset for 50 psi. However, they are field adjustable from 0-150 psi
higher than system pressure. The relief valve should be set 15 psi higher
than the system pressure. Installation should be made as close as possible,
without any valves or accessories between the relief valve and the pump. |
|